Storage Temperature Range:

-4 degrees F to 160 degrees F (-20C to 75C)

Operating Temperature Range:

14 degrees F to 140 degrees F (-10C to 60C)

Dimensions (Veypor device only):

W: 3.0" (76mm) L: 3.9" (99mm) H: 0.8" (20mm)

Weight (Veypor device only):

3.7oz (106g)

Voltage:

8-16VDC

Current:

0.15AMP (150mA)

VR2 Battery Backup:

Lithium-Ion - 10 year life

PC Data Download:

Included serial cable or optional USB adapter.



Acquisition Mode

Sampling Rate

Recorded Variables

Samples per Second

Max Sampling Time

Auto 1/4 Mile Run

25Hz

5

125

28sec

Staged 1/4 Mile Run

25Hz

5

125

28sec

Roll-on Timing

25Hz

5

125

28sec

Dynamometer

25Hz

5

125

28sec

Auto 0-60Mph Run

50Hz

5

250

14sec

VR2 Datalogger

1 to 50Hz

5

250

27hours

Braking Run

50Hz

5

250

14sec



Measurement

Range

Internal Increment

Display Increment

Standard Accuracy

Velocity

0-400Mph
(0-650Kph)

0.0062Mph
(0.01Kph)

0.1Mph
(0.1Kph)

0.05%

Distance

0-999Miles
(0-999Km)

0.039" (1mm)

1ft (1m)

0.05%

Acceleration

+/- 1.7G

0.03 ft/s^2
(0.01 m/s^2)

0.1 Gs

0.05%

RPM

0-30,000

1RPM

2RPM

0.01%

Time

0-6000hours

0.00512s

0.01s

0.003%

 

Copyright DATRON Technology Limited